DC and AC circuit fundamentals
Ohm's law, series and parallel, AC and three-phase, voltage drop and protective devices: enough circuit theory to follow any solar circuit and judge a test reading. You will predict a reading before you measure.
- Core
- Beginner
- about 25 hours
Written by the GreenHired editorial teamSources last checked 20 November 2026How we research roadmaps
Predict every reading before you check it. When prediction and result disagree, either your sums are wrong or something real is wrong, and finding out which is the skill. Practise on paper and in a simulator, in the order solar uses the ideas: V = I x R first, then power, then series and parallel, because a string is series and an array is parallel.
Predicting a string, then an array, before anyone measures
Two strings of ten modules each, every module working at about 40 V and 10 A: round numbers made up for this exercise, not a real datasheet.
- One string, in series: 10 x 40 V = 400 V. The current stays at 10 A. Power is 400 V x 10 A = 4,000 W.
- Two strings, in parallel: the voltage stays at 400 V and the currents add, 10 A + 10 A = 20 A. Power is 400 V x 20 A = 8,000 W, which is 2 x 4,000 W as it should be.
- Now compare with a reading. A string measured with nothing connected (open circuit) will read higher than 400 V, because a module’s operating voltage sits below its open-circuit voltage; see how PV works. A reading far from the prediction, such as half the voltage, means check the sums first (wrong module count, wrong figure from the datasheet), then report it to the person responsible. Test instruments and safe testing shows how the same sums check a real result.
This is a paper exercise. Measuring a live string is for trained, authorised people, and 400 V of DC is enough to kill. Electrical safety for DC and AC solar work explains why the roof is not the place to practise.
What to drill and what to read once
Ohm’s law, power and series and parallel are used every day, so drill them until they are automatic. RMS and three-phase need only enough depth to read a label and a drawing correctly.
Earthing is different: the principles carry over, but the rules are national, so learn the arrangement names used where you will work and read that country’s standard. All 4 UK postings among the 17 job postings sampled (UK, US, Germany, India and Australia; how we research roadmaps) asked for the 18th Edition (BS 7671), so a UK reader should plan to meet earthing and protection rules early.
For voltage drop, learn what the percentage means here, then do the arithmetic in practical maths and units for solar.
What you will learn
- Voltage, current, resistance and power, and how Ohm's law links them
- How series and parallel connections add voltage or current, as in strings and arrays
- The difference between DC and AC, what RMS means and how three-phase differs
- Why long or thin cables lose voltage, and what a 1 percent or 3 percent drop means
- What fuses, breakers and RCDs protect against and why DC ratings matter
- Earthing and bonding in principle, and how to read a simple single-line diagram
The parts of this topic
Voltage, current, resistance and Ohm's lawabout 3 hours
The three basic quantities and the law that links them: V = I x R.
Voltage is the push that moves charge, current is the flow, and resistance opposes it; Ohm's law ties them together as V = I x R. Example: a 12 V source across a 4 ohm resistor drives 3 A. In solar the same law explains why a thin or long cable wastes energy as heat. Watch the units (milliamps, kilo-ohms), and do not apply the law to a PV cell, which does not behave like a simple resistor: use it for cables and loads, not for the module itself.
- Voltage, current, resistance and Ohm's law SparkFun Learn · Guide
- University Physics Volume 2, 9.4: Ohm's law OpenStax (Rice University) · Book
- Ohm's Law simulation PhET Interactive Simulations (University of Colorado) · Tool
Power and energyabout 3 hours
Power is the rate of using energy (watts); energy is power over time (watt-hours). Mixing them up ruins yield figures.
Power is P = V x I, in watts. Energy is power over time: a 5 kW system running flat out for one hour makes 5 kWh. A string at 400 V and 10 A, for instance, carries 4,000 W. A customer's bill is in kWh but the inverter label is in kW, so confusing the two leads to wrong quotes and wrong yield checks. Practise by converting each figure on a datasheet and a bill into the right unit before you compare them.
- Electric power SparkFun Learn · Guide
- University Physics Volume 2, 9.5: electrical energy and power OpenStax (Rice University) · Book
- Electric power Energy Education (University of Calgary) · Guide
Series and parallel circuitsabout 3 hours
Series adds voltage with the same current; parallel adds current at the same voltage, the basis of strings and arrays.
In series the same current flows through every part and the voltages add; in parallel the voltage is shared and the currents add. Example: ten modules of about 40 V each in one string give about 400 V at the module current, and two such strings in parallel give the same voltage at double the current. Modules with different currents in series, or different voltages in parallel, let the weakest one limit the group. That is called mismatch.
- Series and parallel circuits SparkFun Learn · Guide
- University Physics Volume 2, 10.2: resistors in series and parallel OpenStax (Rice University) · Book
- Parallel circuit Energy Education (University of Calgary) · Guide
DC, AC and RMSabout 3 hours
DC flows one way; AC reverses 50 or 60 times a second. The RMS value is the heating-equivalent number on the label.
DC flows one way at a steady voltage; AC reverses direction many times a second (50 Hz in much of the world, 60 Hz elsewhere). The RMS value, such as 230 V or 120 V, is the DC-equivalent heating value, and the peak is higher: a 230 V supply peaks near 325 V. DC is not the safer one: a PV string at several hundred volts DC can kill, and a DC arc does not fade out at a zero crossing. An inverter turns the array's DC into AC for the building.
- Alternating current (AC) vs direct current (DC) SparkFun Learn · Guide
- University Physics Volume 2, 15.1: AC sources OpenStax (Rice University) · Book
- Root mean square Wikipedia · Guide
Single-phase and three-phase suppliesabout 3 hours
Homes usually have one phase; larger buildings use three offset phases that balance large loads and inverters.
A home usually has a single-phase supply; larger buildings use three phases, three AC voltages offset in time, which spread large loads evenly. A three-phase inverter feeds all three phases, and a single-phase inverter feeds one of them. Grid-connection rules often count current per phase, so you need to know which phase equipment is on. Terms differ by country, and North American homes use split-phase supplies, so check your local names before you read a drawing from abroad.
- Three-phase electric power Wikipedia · Guide General explainer; check the sources it cites before relying on a number.
- Electricity delivery to consumers US Energy Information Administration · Guide
Cable resistance and voltage dropabout 3 hours
A cable's resistance makes the far-end voltage lower than at the source; the loss is heat and can trip inverters.
A cable's resistance makes the voltage at the far end lower than at the source, and the loss becomes heat. MIS 3002 asks for AC cables sized to minimise voltage drop, noting that about 1 percent is practicable for most domestic systems and up to 3 percent for larger systems or long runs. A long AC run to an inverter, for example, can push the voltage at the inverter up and cause nuisance trips. Size a cable for its length as well as its current rating.
- MIS 3002 Issue 6.0: the Solar PV Standard (Installation) MCS · Standard Free to read. Dated 18 March 2026; mandatory for contractors certified under it from 18 June 2026. The library also lists a redeveloped MIS 3002:2025 Issue 2.0, so check which one your employer is certified to.
- PVPMC: DC wiring losses Sandia National Laboratories · Guide
- Wiring Unlimited: the book on cabling and DC systems (Victron Energy) Victron Energy · Book Written for battery and low-voltage DC systems; the cable, fuse and voltage-drop ideas apply, the numbers do not transfer to PV strings.
Fuses, breakers and RCDsabout 3 hours
Overcurrent devices protect cables; RCDs protect people from earth leakage. DC and AC ratings are not interchangeable.
A fuse or breaker protects a cable by opening on overcurrent; an RCD (residual current device) opens when current leaks to earth, which protects people. Where a design needs string fuses, they must be DC-rated, and an AC-only breaker is not automatically rated for DC. A DC arc is harder to extinguish than an AC arc, so the DC voltage and current rating on the label matters. Follow the design and the maker's instructions.
- Fuse Energy Education (University of Calgary) · Guide
- Circuit breaker Energy Education (University of Calgary) · Guide
- Residual-current device Wikipedia · Guide General explainer; trip ratings and rules are set by your local code.
Earthing and bondingabout 3 hours
Earthing gives faults a path that trips protection; bonding keeps metalwork at one potential. Rules vary by country.
Earthing connects exposed metal to ground so a fault current trips a protective device; bonding ties metalwork together so it stays at the same potential. Supply earthing arrangements have names (in UK-style codes TN-S, TN-C-S and TT) and they change which protection is needed. Copying an arrangement from another country's code is a common slip, so use the rules of the place you will work and read the paid standard there. A metal roof frame that becomes live in a fault is the shock risk this guards against.
- Grounding Energy Education (University of Calgary) · Guide
- Earthing system (TN-S, TN-C-S, TT and others) Wikipedia · Guide General explainer; the names differ slightly between countries, so confirm with your local code.
Reading schematics and single-line diagramsabout 3 hours
A schematic shows how parts connect, not where they are; PV drawings use a single line for each string group.
A schematic shows how parts connect, not where they sit. PV drawings usually use a single-line diagram: one line stands for each string or circuit, with symbols for modules, fuses, isolators, inverters and meters, and a legend that says what each symbol means. Example: following the drawing to find which isolator controls which string. A drawing may not match the roof: check the legend, check the real wiring, and ask when they differ.
- How to read a schematic SparkFun Learn · Guide Written for electronics, but the symbol and net ideas carry over to PV single-line diagrams.
- What is a circuit? SparkFun Learn · Guide
Practice task
In a free circuit simulator (the PhET circuit kit linked here), build four circuits: three 'modules' as batteries in series feeding a bulb, the same three in parallel, a long thin 'cable' with a resistor to show voltage drop, and a circuit with a fuse that blows. For each, write down the voltage and current you predicted and what the simulator showed, with two sentences on any difference. Finish with a one-page sheet of the formulas you used and one worked example each.
Skills you build
Ohm's lawSeries and parallel circuitsAC and RMSVoltage dropProtection and earthing conceptsReading schematics
Resources for this topic
Every source here is free. Each link opens the provider's own site in a new tab.
- Introduction to Solar Photovoltaic (PV) Installation Southface Institute · Course Free, five modules, US-oriented.
- Introduction to Understanding Solar PV Installations (online) West Nottinghamshire College · Course Free for eligible learners in England aged 19 or over; about 20 hours. Check the eligibility rules.
- Electric circuit Energy Education (University of Calgary) · Guide
- Circuit Construction Kit: DC PhET Interactive Simulations (University of Colorado) · Tool
- Circuits and Electronics (6.002) MIT OpenCourseWare · Course University level and heavier than you need; use it for reference.
Latest Renewable Energy jobs
No title matches the role right now, so these are the latest jobs in the same category.
No live jobs to show right now. Check back soon, or browse every green job.
Spot a problem with this topic?
Tell us what is wrong, missing or unclear here. Your note is attached to this topic.
Notes are sent from this page with JavaScript on. Without it, write to us on the contact page.