Stage 2: Electrical and solar basics · topic 5 of 53

How PV works: sun, cells and I-V curves

How sunlight becomes string output, and why a roof gives less than the number on the module label. You will read an I-V curve and explain what heat, shade and tilt do to output.

  • Core
  • Beginner
  • about 20 hours

Part of the Solar PV technician roadmap: from first safety to mid level

Written by the GreenHired editorial teamSources last checked 20 November 2026How we research roadmaps

What would make a module’s output lower on a real roof than the figure on its label? Ask it at each step of the chain, from sunlight to cell, module and string, and then for every condition that changes the result. Keep your answers: they become a first fault-finding checklist.

A hot afternoon: 400 W becomes 358 W

A 400 W module (its STC label figure) is given a made-up power coefficient of -0.35 per cent per degree C and a made-up voltage coefficient of -0.28 per cent per degree C. Neither is a real datasheet value, so read the coefficients from the datasheet you are using.

On a hot afternoon the cells might reach 55 degrees C, which is 30 degrees above the 25 degrees C of STC. The power falls by 30 x 0.35 = 10.5 per cent, so the module delivers 400 x (1 - 0.105) = 358 W. It lost 42 W with nothing wrong: with these figures, a module at about 90 per cent of its label on a hot afternoon in full sun is behaving normally. Commissioning compares a result with the datasheet corrected for temperature and sunlight, not with the raw label.

A cold morning: 480 V becomes about 527 V

Ten such modules in series, each with an open-circuit voltage of 48 V at STC (also invented), make 480 V at STC. With the cells at -10 degrees C, 35 degrees below STC, the voltage rises by 35 x 0.28 = 9.8 per cent, and the string reads about 480 x 1.098 = 527 V. That rise is why string design uses a cold-day voltage, and why the live voltage on a frosty morning is higher than the label suggests.

These sums feed straight into practical maths and units for solar. PV modules and datasheet reading shows where the coefficients sit on a real datasheet, and sizing, yield estimates and losses turns them into a yearly figure.

Why output dropped: the cheapest question first

A customer says the system produces 8 per cent less than last year. Start with the question that needs no site visit: was the weather different? Compare irradiance for the two periods before you look at the equipment. Next ask whether something new casts a shadow or soiling has built up, because one shaded cell can pull a whole string down and a small new shadow can matter. Then ask whether the drop was sudden or gradual. A sudden step points to a fault such as a failed connector, fuse or bypass diode, while slow ageing is a small fraction each year.

Only then go and look. For how to check a string on site, see finding DC and string faults.

What you will learn

  • How irradiance and peak sun hours describe the solar resource
  • How cells make modules, modules make strings and strings make arrays
  • What the I-V and P-V curves show: Voc, Isc, Vmp, Imp and the maximum power point
  • Why the label power is a laboratory figure and how real conditions change it
  • How temperature, shade, tilt and orientation each change output
  • How modules lose output slowly over their life

The parts of this topic

Irradiance and peak sun hoursabout 3 hours

Irradiance is sunlight power per square metre; peak sun hours turn daily energy into hours at 1,000 W per square metre.

Irradiance is measured in watts per square metre. Insolation is the energy over time, and peak sun hours express a day's insolation as hours at 1,000 W per square metre. Example: 4 peak sun hours on a 5 kWp array suggests roughly 20 kWh before losses. Resource maps and PVGIS give these numbers for a location. Do not mix up hours of daylight with peak sun hours: a ten-hour day may be only three or four peak sun hours.

From cell to module to arrayabout 3 hours

A single cell makes only a watt or two; chains of cells make a module, and modules combine into strings and arrays.

A single PV cell is small and, according to the US Department of Energy, typically produces about 1 or 2 watts; cells are connected in chains inside a protective laminate to make a module, and modules are connected in series (strings) and in parallel (arrays). The Department describes this modular structure as why systems can be sized for almost any need. A module is not one big cell: its cells share current in series, so one weak cell affects the rest. With 60 or 72 cells in series, the module voltage is tens of volts.

I-V and P-V curvesabout 3 hours

The curve of all voltage and current pairs a module can supply, with Voc, Isc and the maximum power point on it.

The I-V curve starts at Isc (short circuit, zero volts) and ends at Voc (open circuit, zero current); the maximum power point, with Vmp and Imp, is where voltage times current peaks. The P-V curve plots that product. An inverter's MPPT, for example, constantly moves the operating point to the top of the P-V curve. A working string runs near Vmp and Imp; Voc and Isc are not operating values but the figures you measure or design against for safety.

Standard test conditions versus real conditionsabout 3 hours

The label power is measured at 1,000 W per square metre and 25 degrees C cell temperature; roofs rarely match that.

STC means 1,000 W per square metre of irradiance, 25 degrees C cell temperature and a defined spectrum (AM 1.5). The kWp of a system is the sum of the module label powers at STC, which is how MIS 3002 defines the figure used in its performance estimate. A 400 W module on a hot, hazy day may deliver well under 400 W. The label is a comparison figure, not a promise of output, and real conditions usually give less peak power.

Temperature and temperature coefficientsabout 3 hours

Heat lowers voltage a lot and raises current only a little; datasheets give the percentage change per degree.

The US Department of Energy notes that higher temperature causes a slight rise in current but a much larger drop in voltage, so modules work best when cool. The datasheet's temperature coefficients give the percentage change in power, voltage and current per degree C. A negative power coefficient means a hot roof array loses power on a sunny day. Remember the cold side too: Voc rises in cold weather, which is why string design uses a cold-day voltage, not the label figure.

Shading, mismatch and bypass diodesabout 3 hours

Shade lowers current, and a shaded cell can pull down a whole string unless bypass diodes route the current around it.

In a series string the current is limited by the weakest part, so shade on one cell can cut a module or string sharply. Bypass diodes inside the module let current skip a shaded section, at the cost of the voltage of that section. A chimney shadow crossing a string in the afternoon is one example of such shade. Mismatch between modules, soiling and dirt behave in a similar way. A small shadow can cost far more than its share of the module's area.

Orientation and tiltabout 3 hours

Tilt and compass direction decide how much sun a surface receives; the best angle depends on latitude and use.

In the northern hemisphere modules face roughly south and tilt at about the local latitude for the highest yearly energy, according to the US Department of Energy, but real roofs and customers' use change the best choice, and where shading, wind loads or cost matter more the perfect angle is not worth chasing. East-west arrays, for example, give a flatter daily profile that suits morning and evening use. You can test a tilt and azimuth quickly in PVGIS.

Degradation and ageingabout 3 hours

Modules lose a little output every year, and component failures add to that; warranties describe the expected curve.

Modules lose a small fraction of their output each year, and some warranties allow a larger loss in the first year. Failed connectors, fuses and bypass diodes add faults on top of normal ageing; the PVPMC page on DC component health describes how failures in a module with three bypass diodes can cut output by a third. Example: a datasheet warranty that guarantees a stated percentage of the original power after 25 years. A sudden drop usually means a fault, not ageing.

Practice task

Use PVGIS (free) to look up a real location near you. Record the yearly energy per kWp for two tilts and two orientations, put the four numbers in a small table, and write six sentences explaining the differences using what you learned about irradiance, temperature and tilt. Add a sketch of an I-V curve with Voc, Isc and the maximum power point labelled, and mark how the curve moves when the module is hotter or partly shaded.

Skills you build

Irradiance and peak sun hoursI-V curve readingStandard test conditionsTemperature effectsShading effectsOrientation and tilt

Resources for this topic

Every source here is free. Each link opens the provider's own site in a new tab.

Back to the whole roadmap

Live jobs

Latest Renewable Energy jobs

No title matches the role right now, so these are the latest jobs in the same category.

All Renewable Energy jobs

No live jobs to show right now. Check back soon, or browse every green job.

Spot a problem with this topic?

Tell us what is wrong, missing or unclear here. Your note is attached to this topic.

Notes are sent from this page with JavaScript on. Without it, write to us on the contact page.