Stage 6: Survey, sizing and basic design · topic 25 of 53

Design and estimating tools

Learn one design or yield tool well enough to defend its numbers and check them against a second source. The subtopics are alternatives: pick the one your employer or region uses.

  • Core
  • Intermediate
  • about 10 hours
  • Pick one

Part of the Solar PV technician roadmap: from first safety to mid level

Written by the GreenHired editorial teamSources last checked 20 November 2026How we research roadmaps

Most of your hours should go on the cross-check, not on the buttons. If you do not yet know which tool an employer will use, PVGIS (free, yield only) and OpenSolar (free, layouts and proposals) are practical starts, pvlib suits learners who code, and CAD matters where plan sets are expected. Whatever you choose, the habit is the same: run one simple house, reproduce the answer a second way and explain the gap.

Explaining a gap between two answers

A 4.5 kWp array faces south at 35 degrees. All the yield figures below are made up, not real PVGIS or MCS values. In this sketch PVGIS reports 1,000 kWh per kWp a year, so the tool says 4.5 x 1,000 = 4,500 kWh.

The second answer uses the standard estimation method in MIS 3002 issue 6.0, Appendix B: annual AC output = kWp x Kk x SF.

  • Kk is looked up in a table of kWh per kWp. The standard’s note says the tables are Climate-SAF-PVGIS data multiplied by 0.8. The note does not say which loss setting that PVGIS data carries, so for the sketch only, assume Kk is the web figure times 0.8: 1,000 x 0.8 = 800. A real table value will differ, which is one more gap to explain.
  • SF, the shade factor, is 1 minus the estimated shade loss. A tree that takes 5% gives SF = 0.95.
  • Annual output = 4.5 x 800 x 0.95 = 3,420 kWh.

Side by side:

  • PVGIS run: 4,500 kWh
  • MIS 3002 method: 3,420 kWh
  • Difference: 4,500 - 3,420 = 1,080 kWh, or 24%

The gap comes from the two factors assumed above: 0.8 x 0.95 = 0.76, and 1 - 0.76 = 0.24. The 0.8 is built into the standard’s tables, and the shade factor is a site input the first run left out. A real comparison will not come out at exactly 24%. Write both lines in your note, and say which figure goes into a proposal and why. The loss figures behind any tool are explained in sizing, yield estimates and losses.

An auto-designed layout is a draft

An auto-designed layout knows the roof outline you drew, not the loft you did not photograph. Check it against the site and roof survey for edges, obstructions and structure, and against the inverter datasheet for string length and current, as in string, inverter and cable design. Label every estimate with its method. In MCS work, MIS 3002 clause 4.1.8 allows an extra estimate beside the standard one only if the approach is described and justified, it is not given greater prominence, and it carries a warning when it is significantly better than the standard result.

Design is paper and screen work. Any electrical work built from your design must be done by a person authorised under your local licensing rules.

What you will learn

  • Pick one tool and learn its inputs, defaults and outputs well enough to defend a number
  • Reproduce the same simple case in a second source, such as PVGIS or a hand calculation, and explain any gap
  • Produce a layout, a bill of materials and a single-line diagram where the tool supports it
  • Know a tool's limits: what it assumes about shade, losses and your local rules, and what only a site visit can confirm

Pick one of these

These are alternatives. Learn the one your employer or course uses; one is enough to complete the topic.

PVGIS (free web calculator)about 10 hours

A free tool from the European Commission that estimates energy from a fixed PV system anywhere it has data. A good first tool and a check on others.

PVGIS asks for location, technology, installed kWp, mounting, slope and azimuth, then reports annual and monthly energy, year-to-year variability and a loss breakdown, downloadable as CSV or PDF. The manual says it defaults to 14% system loss and draws on several radiation databases depending on region. It estimates yield only: it does not draw layouts or strings. Treat the default loss as a starting assumption, not a measurement of your site.

OpenSolar (free design and proposal tool)about 10 hours

Free design software with automatic design, bill of materials, mounting design, single-line diagrams and proposals. Always check its output against datasheets.

OpenSolar's home page describes its software as free and lists design tools (automatic design, bill of materials, mounting designer, single line diagrams), sales proposals and project management. Its pages on shade analysis and permit packs were not opened for this topic, so confirm those features for your region. Auto-design lays out modules, but you still check string length against the inverter datasheet and the layout against the roof edge and structure.

  • OpenSolar OpenSolar · Tool The page says the software is free of charge. Check terms for commercial use.

Aurora (commercial design and permit platform)about 10 hours

A paid platform for design, sales proposals and permit plan sets. No free tier was found, so access probably comes through an employer.

Aurora's site describes design tools, sales tools, plan sets and racking integration, and presents its production estimates as physics-based and checked against real site data. No price or free tier was found, so assume an employer pays. Knowing one product's buttons without knowing what its numbers mean does not transfer, so learn the parts that do: reading a layout, a loss table and a plan set.

pvlib python (code for modelling)about 10 hours

A free open-source Python toolbox for simulating PV systems. It suits learners who want to see every step of a yield calculation.

pvlib python is a community-developed toolbox, free under the BSD 3-clause licence. Its introductory tutorial loads module and inverter specifications, fetches typical-year weather data from PVGIS for several sites, chains solar position, irradiance, cell temperature and DC to AC conversion, then compares two coding styles. It is not a design tool for drawings. If you cannot reproduce a result by hand for one simple case, do not trust it.

CAD for drawings and plan setsabout 10 hours

Plan sets need layout and single-line drawings, drawn in CAD or design software. LibreCAD is a free 2D start; ask which CAD your employer uses.

A plan set usually combines a site plan, roof layout, single-line diagram and labels. LibreCAD describes itself as a free open-source 2D CAD application for Windows, macOS and Linux under GPLv2. PVsyst, AutoCAD and HelioScope appear in some job adverts, but their pages were not opened, so they are not linked here. A drawing is useful only if an installer can build from it: draw to scale and show ratings and cable sizes.

  • LibreCAD LibreCAD project · Tool Free, open-source 2D CAD. Practise drawing a roof layout to scale.

Practice task

Model one sample house in your chosen tool and write a half-page note: the inputs you chose, the tool's annual kWh, the same figure from PVGIS or a hand calculation, the gap and your explanation for it, and one assumption you changed or would check on site.

Skills you build

Yield estimation softwarePV layout and single-line drawingReading a tool's assumptions

Resources for this topic

Every source here is free. Each link opens the provider's own site in a new tab.

Back to the whole roadmap

Live jobs

Jobs related to Solar PV technician

No title matches the role itself right now, so these are live jobs in the same field.

All Renewable Energy jobs

Spot a problem with this topic?

Tell us what is wrong, missing or unclear here. Your note is attached to this topic.

Notes are sent from this page with JavaScript on. Without it, write to us on the contact page.