Stage 3: Carbon accounting with the GHG Protocol · topic 11 of 47

Emission factors, GWPs and public datasets

An emission factor turns activity data, such as kWh or litres, into tonnes of CO2e. You will pick the right dataset for each activity, log it with its year and GWP version, and refresh it each cycle.

  • Core
  • Intermediate
  • about 10 hours

Part of the ESG analyst roadmap: from the basics to mid level

Written by the GreenHired editorial teamSources last checked 20 November 2026How we research roadmaps

Choose the source after you know the activity and its unit. List what you hold (kWh, litres, passenger-km, tonnes of waste, or only money spent), pick the most specific official dataset for that unit and country, read its year and GWP version, and write all of it into the factor log before you calculate anything. Spend-based and life-cycle factors are the fallback for activities with no physical data or no national table.

A factor change that looks like a saving

A UK office uses 200,000 kWh of grid electricity in both 2025 and 2026. Neither factor below is a real DESNZ value; both are made up for the example.

  • 2025 file: 200,000 kWh x 0.20 kg CO2e per kWh = 40,000 kg, or 40 tonnes.
  • 2026 file: 200,000 kWh x 0.18 kg CO2e per kWh = 36,000 kg, or 36 tonnes.

The report shows a 10% fall: (40 - 36) / 40 = 0.10. Nobody used less power; the factor changed. With a factor log you can state that activity moved 0% and the factor moved 10%, and the method note of the inventory project can say so, instead of letting a reader see a saving that never happened. That is also why you keep last year’s row: it reproduces last year’s number and lets you separate the two effects.

Matching the source to the activity

Scope 1 and 2 data usually arrive in physical units (litres, kWh), so a government set fits them: Scope 1 and 2 calculations covers the choices between methods. Scope 3 purchases often arrive as money only, which is where spend-based factors earn their place, with the caveat that a price change alone moves the result. Anything built on them is an estimate, and Scope 3 across the value chain shows how to replace them with better data.

Apply one family per activity and region, and say which in the log. Two sets mixed on one site produce differences nobody can explain later.

What you will learn

  • Explain what an emission factor is, what unit it needs and where official factor sets come from.
  • Find and use the UK DESNZ conversion factors and the US EPA Emission Factors Hub with eGRID.
  • Use IPCC resources for sources and processes that national tables do not cover.
  • Know when spend-based (input-output) factors or life-cycle databases are the only option, and their limits.
  • Keep a factor log with name, year, GWP version, unit and download date, and refresh it each cycle.

The parts of this topic

UK DESNZ conversion factorsabout 2 hours

The UK government's annual factor file for fuels, electricity, travel, water and waste, with a methodology report.

The UK government publishes conversion factors every year so companies can turn activity data into emissions. The collection page says each update comes with a methodology report and a major-changes report, and that the factors are relevant to the Environmental Reporting Guidelines, including SECR. The 2026 set is listed there. Example: kg CO2e per kWh of grid electricity, per litre of diesel, per passenger-km of rail. Two slips to avoid: using last year's file for this year's report, and reading the wrong sheet or scope tab.

US EPA Hub and eGRIDabout 2 hours

The US set: a yearly Excel hub of factors, with electricity rates by grid subregion from eGRID.

The EPA Emission Factors Hub gathers factors for stationary and mobile combustion, purchased electricity, upstream and downstream transport, business travel, commuting and waste. Its 2025 update notes factors from eGRID, EPA's database of power-plant emissions and generation, which gives electricity rates by US subregion. A site in a regional grid uses that region's eGRID rate, not the national average. The hub uses AR5 GWPs (AR4 for its waste factors), so record that next to every factor you take from it.

IPCC guidelines and the EFDBabout 2 hours

The international source for national inventory methods and factors, useful when no national table fits.

The IPCC's Task Force on National Greenhouse Gas Inventories publishes the 2006 Guidelines and the 2019 Refinement, with volumes for energy, industrial processes, agriculture and waste, and hosts the Emission Factor Database. Companies use them for process emissions, such as a chemical plant's process factor, or for countries with no official factor set. The EFDB page says it is being renovated, so its content may change. If a published local factor exists for your country or technology, prefer it to an IPCC default.

India's grid factorabout 1 hour

India's national electricity factor comes from the Central Electricity Authority; confirm the current edition yourself.

For Indian sites, the usual source of a grid emission factor is the Central Electricity Authority (CEA) under the Ministry of Power, which publishes a baseline database for the power sector. As read on 20 November 2026, the linked page is the CEA home page only: the database page and its current edition could not be confirmed, and an older address returned an error. Find the database on the CEA site, record the version and date, and ask your auditor which edition they accept. Never quote a figure from a blog.

Supplier and residual-mix factorsabout 1 hour

For market-based Scope 2 you also need supplier-specific factors and, in Europe, the residual mix.

Market-based electricity needs more than a grid average. AIB publishes European residual mixes, which show the supply not covered by guarantees of origin and help avoid double counting. A supplier's own disclosed factor can also be used if it meets the Scope 2 quality criteria. Check that the residual mix is for the right year, and never mix a supplier factor with a grid average for the same site. A company with a green tariff uses a supplier factor; one without uses the residual mix for its country.

Spend-based (input-output) factorsabout 2 hours

Factors per unit of money by industry, built from national or global economic tables; coarse but widely available.

Environmentally-extended input-output (EEIO) models link economic flows between industries to emissions, producing factors in kg CO2e per unit of currency. The US EPA's USEEIO is one model; EXIOBASE is a global multi-regional one. They suit Scope 3 screening because purchase ledgers are easy to get: a factor for 'paper products', for instance, is applied to a spend total. The factors sit in a base-year currency, so adjust for inflation and exchange rates, and remember that one price change moves the answer with no change in real emissions.

Life-cycle assessment databasesabout 2 hours

Product and material factors from LCA databases; some are commercial, some open, and the software to use them is free.

Life-cycle assessment (LCA) databases give cradle-to-gate factors for materials and products, such as a tonne of steel or a kilogram of plastic. The ecoinvent database requires a licence; openLCA describes itself as free LCA software with many available databases. A packaging firm, for instance, uses a plastic resin factor from a licensed database. Factors from different databases can have different system boundaries, so mixing them can make one product look better or worse than another for no real reason.

Factor vintage log and GWP setabout 1 hour

A register of every factor used, with year, unit, source and GWP version, so numbers can be refreshed and defended.

A factor log is a table with one row per factor: name, value, unit, source, year of publication, GWP version and date downloaded. It makes year-on-year changes explainable, shows when a lower figure comes from a new factor rather than lower activity, and lets an auditor retrace each calculation. The GHG Protocol's AR6 table helps you check which GWP a source uses. Example: grid electricity factor 2024 versus 2025. Adding new rows each year instead of overwriting old ones keeps last year's number reproducible.

Practice task

Build a factor register in a spreadsheet for ten activities (for example grid electricity, natural gas, diesel, a short-haul flight, a rail trip, waste to landfill, purchased paper, water and a refrigerant). For each, record the factor, unit, source page, year, GWP version and why you chose it over an alternative; then write a half-page guide to refreshing it next year.

Skills you build

Choosing emission factorsUK DESNZ and US EPA datasetsSpend-based and LCA factorsFactor vintage loggingReading dataset documentation

Resources for this topic

Every source here is free. Each link opens the provider's own site in a new tab.

Back to the whole roadmap

Live jobs

Live ESG analyst jobs

Roles whose title matches this career path.

All ESG & Sustainability Reporting jobs

Spot a problem with this topic?

Tell us what is wrong, missing or unclear here. Your note is attached to this topic.

Notes are sent from this page with JavaScript on. Without it, write to us on the contact page.