Stage 3: Carbon accounting with the GHG Protocol · topic 8 of 47

GHG Protocol Corporate Standard in practice

Set the boundaries, scopes, gases and base year that every credible greenhouse gas inventory starts from. You will write an inventory design note and a recalculation rule before collecting any data.

  • Core
  • Intermediate
  • about 18 hours

Part of the ESG analyst roadmap: from the basics to mid level

Written by the GreenHired editorial teamSources last checked 20 November 2026How we research roadmaps

A greenhouse gas inventory is a set of written decisions with calculations hanging off them. Make the decisions in a fixed order before you open a single invoice: consolidation approach, boundary, base year, gases and GWP set, recalculation rule, then data owners. When two methods are possible, the five principles settle the choice.

How the consolidation approach moves a hotel group’s total

A group runs three hotels it owns and operates (A, B, C) and holds 50% of a fourth (D) that a partner runs. Treat the yearly emissions as made up: A 400, B 600, C 500 and D 1,000 tonnes CO2e, with D’s figure being its own Scope 1 and 2.

  • Operational control: Scope 1 and 2 = 400 + 600 + 500 = 1,500 tonnes. D is outside Scopes 1 and 2.
  • Equity share: 1,500 + 0.5 x 1,000 = 2,000 tonnes, which brings in D’s 500 tonnes.

The Scope 3 Standard (box 5.1, as read on 20 November 2026) says that under operational control, emissions from an operation you part-own but do not control go in Scope 3 as an investment, in proportion to your equity share. So the same 500 tonnes appear in category 15 instead (see Scope 3 across the value chain). It also says to use one consolidation approach across Scopes 1, 2 and 3. Neither choice is wrong: the note says which was used, and every later year uses it.

The rest of the design note, in order

List what is in (boilers, vehicles, refrigerant leaks, purchased electricity) and what is out, each exclusion with a reason and a rough size. Pick the base year. Name the seven gases and one GWP set. Give every data source an owner; Scope 1 and 2 calculations covers the arithmetic.

A recalculation rule fixed before the results

The Standard asks for a policy and makes no recommendation on a threshold. For this example only, use an invented rule: recalculate the base year if a structural change moves base-year emissions by more than 5%. Base year is 1,500 tonnes, so 5% is 75 tonnes.

  • Year 3, the group starts running a fifth hotel that emitted 60 tonnes in the base year: 60 / 1,500 = 4%. Below the line, so no recalculation, but log the decision.
  • If that hotel had emitted 150 tonnes: 150 / 1,500 = 10%. Recalculate, and the base becomes 1,650 tonnes.

What “in accordance” asks for

A report can say it follows the Standard only with the required content, so fill in the reporting template with placeholders first (the inventory project puts it to use). Of 16 job postings in our sample (UK, EU, US and India; how we research roadmaps), 7 asked for Scope 1-3 or GHG Protocol work and 4 named the GHG Protocol outright, so use the Standard’s terms in your design note.

The standards are being revised: as read on 20 November 2026, GHG Protocol’s feedback page expects a draft consolidated Corporate Standard for consultation in Quarter 2 2027. Check that page before you fix a method into a long-term process.

What you will learn

  • State the five accounting principles and use them to settle a judgement call.
  • Choose between the equity share, financial control and operational control approaches, and explain what each includes.
  • Define scopes 1, 2 and 3 and draw an operational boundary for a simple company.
  • Apply the required gases and a single set of GWP values, and say where the values come from.
  • Set a base year, write a recalculation policy and plan an inventory management process.

The parts of this topic

The five accounting principlesabout 2 hours

Relevance, completeness, consistency, transparency and accuracy: the tests behind every judgement call in an inventory.

The Corporate Standard says reporting should follow five principles. Relevance: reflect the company's emissions and serve users' decisions. Completeness: account for all sources within the boundary and justify exclusions, so leaving out a small site is acceptable only if you disclose and justify it. Consistency: use the same methods over time and document changes. Transparency: leave a clear audit trail. Accuracy: neither over nor under actual emissions, as far as can be judged. Use the principles as the reason behind each method choice, not as a checklist.

Equity share, financial control, operational controlabout 3 hours

How you decide which businesses and sites count as 'yours' when ownership and control differ.

Under the equity share approach, a company accounts for emissions from operations according to its share of ownership. Under a control approach it accounts for 100% of emissions from operations it controls, using either financial control or operational control as the test. Example: a company with a 40% joint venture it operates would count all of it under operational control but 40% under equity share. Pick one approach and apply it consistently, because mixing approaches between sites or years breaks comparison.

Scopes and the operational boundaryabout 2 hours

Scope 1 is direct, Scope 2 is purchased energy, Scope 3 is everything else in the value chain; the boundary lists what is in.

Scope 1 covers direct emissions from sources the company owns or controls, such as boilers and vehicles. Scope 2 covers emissions from purchased electricity, steam, heat and cooling. Scope 3 covers other indirect emissions up and down the value chain. The operational boundary decides which of these activities you include. For a bank, the biggest emissions may be in Scope 3, from its loans. Reporting only Scopes 1 and 2 and calling it the whole footprint misleads, so always state what is excluded.

Required gases and GWP choiceabout 2 hours

Report all seven Kyoto gases using 100-year GWPs from one IPCC report, and say which report you used.

A 2013 amendment says companies shall report all gases required by the UNFCCC and Kyoto Protocol at the time: CO2, CH4, N2O, HFCs, PFCs, SF6 and NF3. It also says they shall use 100-year GWP values from the IPCC, should use the most recent assessment report, shall use one report for any one inventory where possible and shall report the source. Switching from AR5 to AR6 changes the CO2e of methane, which is why updating GWPs for the current year but not the base year leaves a trend that means nothing.

Base year and recalculationabout 3 hours

Choose a reference year, and recalculate it when the company's structure or method changes so trends stay comparable.

A base year is the year against which emissions are compared over time. The Standard asks you to set a recalculation policy and say what 'significant' means for your company; it makes no specific recommendation on a threshold, so set yours before you see the numbers, or it stops being a rule. Typical triggers are acquisitions, divestments, mergers and errors found later: buying a plant adds emissions in the current year, so the base year is recalculated to include that plant's earlier emissions.

Inventory management planabout 2 hours

A written plan for who collects what data, by when, with which methods and checks, so the inventory can be repeated.

An inventory management plan (IMP) records the processes that produce the inventory: roles and responsibilities, data sources, calculation methods, quality checks, record keeping and how data are reviewed. The EPA provides guidance and a checklist. In a one-page IMP that means naming the finance contact for utility bills, the deadline for each site and where files are stored. It protects continuity when a person leaves. Write it for the second inventory, not only the first, or you will not be able to repeat the work next year.

Reporting template and required contentabout 2 hours

What a report 'in accordance with' the Standard must contain, and a Word template to start from.

A public report in accordance with the Corporate Standard shall include a description of the company and inventory boundary, including the chosen consolidation approach, along with emissions by scope, the base year and other required items listed in the Standard. GHG Protocol provides a reporting template (February 2017) as a Word file. Filling it with placeholders before collecting data shows which information you must gather. Do not claim 'GHG Protocol compliant' unless the report covers all the required items.

What the Standard does not cover, and its revisionabout 2 hours

Verification, offsets and target-setting methods sit outside the core rules, and a consolidated revision is under way.

The Standard focuses on accounting and reporting of emissions. It says it is designed to produce a verifiable inventory but does not provide a standard for how verification should be conducted. Offsets are reductions bought elsewhere, and emissions are reported separately from them. GHG Protocol's feedback page says a draft consolidated Corporate Standard is expected for public consultation in Quarter 2 2027, and records Scope 2 consultations held from 20 October 2025 to 31 January 2026. The 2004 text is not permanent, so check that page before relying on a rule.

Practice task

Choose a real organisation with a few sites (a university, a hotel group or a small manufacturer). Write a two-page inventory design note: the consolidation approach and why, which sites and activities are in and out, the base year, the gases and GWP set, who owns each data source, and your recalculation rule. Fill in the GHG Protocol reporting template with placeholders.

Skills you build

Organisational boundaryScopes 1, 2 and 3GWP choiceBase year recalculationInventory management planGHG Protocol reporting

Resources for this topic

Every source here is free. Each link opens the provider's own site in a new tab.

Back to the whole roadmap

Live jobs

Latest ESG & Sustainability Reporting jobs

No title matches the role right now, so these are the latest jobs in the same category.

All ESG & Sustainability Reporting jobs

No live jobs to show right now. Check back soon, or browse every green job.

Spot a problem with this topic?

Tell us what is wrong, missing or unclear here. Your note is attached to this topic.

Notes are sent from this page with JavaScript on. Without it, write to us on the contact page.