Scope 1 and 2 calculations
Calculate direct emissions and purchased-energy emissions with the right method, the right factor and a documented source. You will report electricity two ways and explain why the totals differ.
- Core
- Intermediate
- about 25 hours
Written by the GreenHired editorial teamSources last checked 20 November 2026How we research roadmaps
Scope 1 and 2 figures are built the same way: activity data, converted into the unit the factor expects, multiplied by the factor, then expressed as CO2e. Document each link (see auditable spreadsheets). Do Scope 1 sources first (fuel, vehicles, refrigerants), then electricity twice, location-based and market-based, then purchased heat, steam and cooling, logging each factor’s name, year and GWP version as you use it.
A small office, end to end
None of these numbers or factors is real; they only show the method.
Scope 1:
- Gas boiler: 50,000 kWh x 0.2 kg CO2e per kWh = 10,000 kg, or 10 tonnes.
- One refrigerant top-up: 5 kg of an HFC with a GWP of 2,000 (made up) = 5 x 2,000 = 10,000 kg, or 10 tonnes. The real GWP depends on the gas, so look yours up.
- Scope 1 total: 20 tonnes. In this made-up case the leak equals a year of gas heating, so refrigerants must not be skipped.
Scope 2, for electricity use of 100,000 kWh:
- Location-based, grid average of 0.4 kg per kWh: 100,000 x 0.4 = 40,000 kg, or 40 tonnes.
- Market-based: certificates retired in the company’s name cover 60,000 kWh, counted as zero for this example. The other 40,000 kWh uses a residual mix of 0.5 (made up): 40,000 x 0.5 = 20,000 kg, or 20 tonnes.
Report both: 40 tonnes location-based and 20 tonnes market-based. The half-page note explains the gap: certificates covered 60% of use, and the rest was priced at the residual mix instead of the grid average.
Slips that change the numbers, and the fixes
A gas bill in kWh meets a per-litre factor. Write the unit beside every factor and check that the activity column matches it.
A new factor file gets mistaken for progress. With consumption flat at 100,000 kWh and the grid factor falling from 0.40 to 0.34 (made up), 40 tonnes becomes 34, a 15% fall with no real change. Re-run last year’s activity with the new factor so the two effects show separately.
A market-based claim has no retired certificate behind it. Check retirement and the Scope 2 quality criteria first. Without them, do not count the claim: use the residual mix if one is published, and say so.
Heat and cooling go missing when the invoice comes from a landlord, not a utility. Ask property managers for service-charge breakdowns.
The factor file and the rules to check
The boundary comes from the GHG Protocol Corporate Standard. Which factor file you use depends on where the site is: see emission factors and datasets. SECR comes up in UK adverts: 2 of the 16 postings sampled (UK, EU, US and India; how we research roadmaps) named it, and both were UK roles, so check the UK factor file and the SECR guidance if you are aiming there.
The Scope 2 Guidance is under review, so as read on 20 November 2026 check GHG Protocol’s page before building a method into a long process.
What you will learn
- Calculate emissions from fuel burned in boilers, generators and vehicles from activity data and a factor.
- Estimate refrigerant leakage and know when process emissions need a specialist method.
- Report electricity emissions with both the location-based and market-based methods and explain the difference.
- Judge whether a renewable certificate or contract qualifies, and avoid double counting.
- Pick a regional emission factor set, log its year, and note the GWP version it uses.
The parts of this topic
Stationary combustionabout 3 hours
Fuel burned in boilers, furnaces and generators: activity data times an emission factor, summed across fuels.
Stationary combustion covers fuel burned in boilers, furnaces, heaters, turbines and similar equipment. The usual method multiplies the quantity of each fuel (litres, cubic metres, kWh or tonnes) by a factor for CO2, CH4 and N2O, then converts to CO2e. The EPA guidance applies to owned or leased sources inside the inventory boundary. Mixing gross and net calorific values, or using a per-litre factor on a volume you recorded in kWh, gives a wrong answer. A gas bill in kWh takes the gas factor per kWh.
- Direct emissions from stationary combustion US EPA Center for Corporate Climate Leadership · Guide
Mobile combustionabout 3 hours
Fuel burned in company-owned or controlled vehicles, calculated from fuel or distance, and kept out of Scope 3.
Mobile combustion covers road, rail, air and water vehicles the company owns or controls. Fuel-based calculations use litres of petrol or diesel; distance-based calculations use kilometres and a per-kilometre factor when fuel records are missing. A fleet card gives litres by vehicle, which is better than estimating from mileage. Employee-owned cars used for work travel belong in Scope 3, not here. Count each litre once: fuel cards and expense claims can describe the same fuel.
- Direct emissions from mobile combustion US EPA Center for Corporate Climate Leadership · Guide
Refrigerants and fugitive emissionsabout 3 hours
Gases that leak from air conditioning, chillers and refrigeration, which have very high warming potentials.
Refrigerants such as HFCs leak from air conditioning and cooling equipment. EPA guidance describes a screening method based on equipment type and a material balance method, an equation that uses opening and closing stock, purchases, sales and the refrigerant held in equipment to find what was lost. Topping up 5 kg of an HFC can be a larger climate effect than a year's electricity at a small office, because the gas has a high GWP. Refrigerants get left out when the data sit with facilities contractors, so ask for their service records.
- Direct fugitive emissions from refrigeration, air conditioning, fire suppression and industrial gases US EPA Center for Corporate Climate Leadership · Guide
Process emissionsabout 2 hours
Emissions released by chemical or physical processes rather than fuel burning, such as cement making or some chemical production.
Process emissions come from the process itself, for example CO2 released when limestone is heated in cement production, or fluorinated gases from some manufacturing. Most office-based and service companies have none. For those that do, methods usually come from sector tools or from the IPCC's national inventory guidelines, whose Volume 3 covers industrial processes and product use. A ceramics plant needs a process factor for its raw materials as well as fuel, and a generic fuel factor will not estimate these correctly.
- 2006 IPCC Guidelines, Volume 3: Industrial Processes and Product Use IPCC Task Force on National Greenhouse Gas Inventories · Guide Written for national inventories; useful to understand the source of sector methods.
Location-based vs market-based electricityabout 5 hours
Two ways to count the same electricity: the average grid mix where you consume it, and the mix you bought through contracts.
The GHG Protocol says companies with operations in markets that offer product or supplier-specific data in the form of contractual instruments shall report Scope 2 two ways, labelled by method: location-based and market-based. This is called dual reporting. Location-based uses the average emission factor of the grid where the electricity is used. Market-based reflects what you chose to buy. A site on a coal-heavy grid with a green tariff, for instance, has a high location figure and a low market figure. Reporting only the lower one without saying so misleads.
- Indirect emissions from purchased electricity US EPA Center for Corporate Climate Leadership · Guide Practical guidance for quantifying both totals.
RECs, guarantees of origin and PPAsabout 4 hours
Certificates and contracts that can lower market-based emissions, and the quality rules and residual mix that stop double counting.
The Scope 2 Guidance lists energy attribute certificates (such as GOs in Europe and RECs in the US), direct contracts such as power purchase agreements (PPAs), supplier-specific emission rates and the residual mix as the instrument types. Certificates must meet Scope 2 Quality Criteria. The residual mix is the supply left over after tracked claims are removed; in Europe, AIB publishes it. Using an average grid factor after buying certificates counts the same renewable power twice. Claim only certificates that were retired in your name.
- Renewable electricity procurement US EPA Center for Corporate Climate Leadership · Guide Covers retiring, allocating and documenting RECs.
- European Residual Mix Association of Issuing Bodies · Dataset
Purchased heat, steam and coolingabout 2 hours
District heating, steam and chilled water bought from a supplier count in Scope 2 alongside electricity.
Scope 2 covers emissions from the purchase of electricity, steam, heat or cooling. District heating networks, steam from a neighbouring plant and chilled water all fall here. The calculation is the same pattern as electricity: quantity bought times a factor, preferably from the supplier or a national dataset. A hospital on a district heating network uses the network's published factor. These are easy to forget when the invoice comes from a landlord or a service charge rather than a utility.
- Scope 1 and Scope 2 inventory guidance US EPA Center for Corporate Climate Leadership · Guide
Factor vintage and GWP versionabout 1 hour
Every factor has a year and a GWP basis; an inventory should record both so comparisons and re-runs are fair.
Emission factor sets are updated every year, and each is built on a GWP set. The EPA's 2025 Emission Factors Hub, for example, states it uses IPCC AR5 values (its waste factors use AR4), while the GHG Protocol's August 2024 table recommends AR6, the latest. Updating to a new year's electricity factor can reduce your figure even if consumption is flat, so a lower number is not progress when only the factor changed. Keep a log with factor name, year, GWP version and download date.
- IPCC Global Warming Potential values (August 2024) GHG Protocol · Dataset
Regional factors: UK, US and Indiaabout 2 hours
Use the official factor set for each country of operation: DESNZ in the UK, EPA and eGRID in the US, and Indian grid data.
The UK government publishes conversion factors each year; the collection page lists a 2026 set, and says the factors are relevant to the Environmental Reporting Guidelines, including SECR. In the US, the EPA hub includes eGRID-based electricity factors by subregion, and the eGRID page discusses the eGRID2023 edition. For India, the Central Electricity Authority is the usual source of the grid factor; as read on 20 November 2026, its current page could not be opened, so confirm the latest publication on the CEA site. Do not apply one country's factor to another country's sites.
- Greenhouse gas reporting: conversion factors 2026 UK Government (DESNZ) · Dataset
- Emissions and Generation Resource Integrated Database (eGRID) US EPA · Dataset
- Environmental reporting guidelines including SECR UK Government · Law or regulation UK guidance on mandatory greenhouse gas reporting.
- Central Electricity Authority (India) Government of India, Ministry of Power · Dataset Home page only: we could not confirm the grid-factor page; look for the CO2 baseline database.
Practice task
For a small organisation with two sites, calculate Scope 1 (natural gas, diesel and one refrigerant top-up) and Scope 2 (electricity and one heat source) for one year using official factors for your region. Report Scope 2 two ways, show every factor with its source and year, and add a half-page note explaining why the two Scope 2 figures differ.
Skills you build
Stationary and mobile combustionRefrigerant and fugitive emissionsLocation-based and market-based Scope 2Contractual instrumentsRegional emission factors
Resources for this topic
Every source here is free. Each link opens the provider's own site in a new tab.
- Scope 2 Guidance GHG Protocol · Standard As of November 2026 the guidance is under review: public consultations ran from 20 October 2025 to 31 January 2026.
- Scope 2 Guidance (PDF) GHG Protocol · Standard
- UK government conversion factors for company reporting UK Government (DESNZ) · Dataset
- GHG Emission Factors Hub US EPA · Dataset
- Scope 2 recorded webinar GHG Protocol · Course The provider offers a free version without a certificate and a USD 30 version with one, as of November 2026.
Live ESG analyst jobs
Roles whose title matches this career path.
Spot a problem with this topic?
Tell us what is wrong, missing or unclear here. Your note is attached to this topic.
Notes are sent from this page with JavaScript on. Without it, write to us on the contact page.