Diagnostic instrument families
Six families of instrument for diagnosing PV faults, from I-V tracers to string analytics. Pick the family your employer uses and learn what it measures, where it misleads and who may use it.
- Core
- Intermediate
- about 8 hours
- Pick one
Written by the GreenHired editorial teamSources last checked 20 November 2026How we research roadmaps
Which question needs answering: where is the loss, where is the heat, why is the curve the wrong shape, does the insulation hold? Each family of instrument answers a different one, so choose by the question, not by the gadget. Pick the family your target employer uses and learn it from free documentation and datasheets. The buttons change between makes. The measurement principle does not.
What each instrument answers on one flagged table
On a ground-mounted plant, string analytics ranks one table of modules as losing the most energy, and a drone survey shows a hot patch on it. This illustrative sequence is not a procedure for a real plant.
- Drone survey, answering where: Sitemark’s article says drones cannot see into electrical cabinets, so treat the scan as an overview, not a diagnosis.
- Handheld thermal camera, checking the patch: only in valid conditions. The IEC TS 62446-3 figures quoted in the DTU slides are above 600 W/m2, wind below 28 km/h and low cloud. Note emissivity and viewing angle with every image.
- I-V trace, saying why: a step in the curve points at a bypass diode, a low voltage ratio at maximum power at series resistance. The tracer connects to a live DC source, so an authorised user takes it.
- Rating check, before connecting anything: Solar Power World’s technician article says commercial arrays in the United States are generally designed for up to 1,500 V DC on the ground and 1,000 V DC on rooftops. The Seaward PV210 data sheet lists open-circuit voltage up to 1,000 V DC. A 1,500 V string is outside that range, so that instrument cannot be used on that array, and the current rating gets the same check.
Postings are a guide to which family to learn: in our sample of 17 job postings (UK, US, Germany, India and Australia; how we research roadmaps), 2 named test equipment (multimeter, Megger, I-V curve tracer, torque wrench and thermal camera among them), both US commissioning or O&M roles.
Before any connection: ratings, calibration, permission
Read the voltage, current and category ratings against the circuit. Check the calibration date and that the proving check passes. Confirm your rules let you use the instrument, because several of these connect to a live DC source or a live enclosure. HSE’s GS38 is the UK guidance on test leads, probes and instruments, and its principles apply anywhere. Test instruments and safe testing goes through the checks in order.
Next, use the instruments on a real fault in DC fault finding, or see how they are scaled up in commissioning and acceptance testing at scale.
What you will learn
- What each family of instrument measures and what it cannot tell you.
- How to read an instrument's voltage, current and category ratings before you connect anything.
- How sunlight, wind and viewing angle change what an infrared image means.
- Why the principle matters more than the make, and how to learn a new instrument from its manual.
- Which instruments are for trained, authorised users only.
Pick one of these
These are alternatives. Learn the one your employer or course uses; one is enough to complete the topic.
Handheld I-V curve tracerabout 2 hours
Sweeps a module or string from open circuit to short circuit, plots the curve and corrects it to standard conditions.
A tracer plots current against voltage and, with irradiance and temperature readings, corrects the curve to standard test conditions so it can be compared with the datasheet. It connects to a live DC source, so only trained, authorised staff use it. It is the main tool for spotting shading, series resistance, shunting and bypass diode problems. Learn the curve shapes first; the buttons differ by make. A curve taken in unstable light or with a poor lead contact can look like a fault when it is not.
- What is I-V curve tracing in solar? Fluke · Guide Vendor blog from a tester maker; the explanation is general
Handheld thermal cameraabout 1 hour
Shows heat on modules, connectors, fuses and enclosures; conditions and technique decide whether the image can be trusted.
The IEA PVPS slides from DTU quote the IEC TS 62446-3 conditions of above 600 W/m2, wind below 28 km/h and low cloud, and show how hot spots from soiling, cracked cells and shorted bypass diodes look as sunlight changes. Resolution, emissivity and viewing angle all alter readings, so a temperature number with no note of emissivity and angle means little. Opening a live enclosure for a better view is not an option: a hot connector inside a combiner box, for instance, is found under the authorised procedure.
- Frame conditions for thermography inspections of PV plants IEA PVPS Task 13 (DTU slides) · Guide Slide deck, 2025
Drone thermographyabout 2 hours
A drone with a thermal camera scans large roofs and fields fast, but it gives an overview, not a diagnosis.
A drone overview scan is a starting point, not a finished diagnosis. Raptor Maps' flight guidelines ask for plane-of-array irradiance of at least 600 W/m2, an energised site, enough image overlap and proof of irradiance such as a pyranometer photo. Sitemark's article admits parts of IEC TS 62446-3 are impractical for drones and that drones cannot see into electrical cabinets. Pilot rules apply: 2 of the 5 US postings in our sample asked for an FAA Part 107 licence, so check your national aviation authority.
- Solar PV inspection drone flight guidelines Raptor Maps · Guide Vendor guidance for its own data service; useful as a flight-planning checklist
Insulation tester and earth-fault locatorabout 1 hour
Measures resistance between live conductors and earth, and helps narrow a leak down to a string or a cable section.
An insulation tester applies a chosen test voltage and reads the resistance to earth; apply only a test voltage the equipment can take, and follow the maker's instructions and the written procedure. Locators help find where along a cable a leak is. The Solar Power World technician article lists insulation resistance testing, earth testing and cable fault location among a technician's tools. The Victorian safety guideline warns that solar DC supply cables may still be live with the power off, because light on the modules keeps them energised, so the method must control the source.
- PV Installers Safety Guideline Energy Safe Victoria and WorkSafe Victoria · Guide Victoria, Australia
Combined PV commissioning testerabout 2 hours
One instrument that performs the commissioning tests and the I-V trace, with its own limits you must check against the array.
The Seaward PV210 data sheet is one example: it lists I-V tracing in line with IEC 61829, insulation and earth-continuity tests, open-circuit voltage up to 1,000 V DC, short-circuit current up to 15 A, and an irradiance meter to convert results to standard conditions. Those ratings show why you check an instrument's limits against the array before connecting. Other makers sell similar kits. Never exceed the instrument rating, and do not use a unit that is out of calibration.
- Seaward PV210 solar PV tester and I-V curve tracer data sheet Seaward · Guide Vendor data sheet used only as an example of ratings; not an endorsement
String-monitoring analyticsabout 1 hour
Software that ranks strings by lost energy using data already collected; it tells you where to look, not what is broken.
Analytics reads data from inverters, optimisers and sensors and flags strings that deviate from neighbours or from a model, for instance as a ranked list of the ten strings losing the most energy. It does not replace site tests, but it focuses them. IEA PVPS reviews describe fault detection from electrical signatures, history, prediction and comparison, and a statistical method that grades small-system health from inverter data and weather forecasts. Check data quality and sensor health before you trust a score.
- Improving efficiency of PV systems using statistical performance monitoring IEA PVPS Task 13 · Guide Free PDF, 2017
Practice task
Choose one family from the subtopics and write a two-page instrument brief: what it measures, the standard it supports, its published ratings, three conditions that make its readings unreliable, and which person may use it under your local rules. Use only free documentation and datasheets. Do not buy, borrow or connect an instrument to do this task.
Skills you build
Instrument selectionReading instrument ratingsInterpreting measurementsSafe test practice
Resources for this topic
Every source here is free. Each link opens the provider's own site in a new tab.
- GS38: electrical test equipment for use on low voltage systems HSE (United Kingdom) · Guide Free copy; UK guidance on test leads, probes and instruments
- Day in the life of a renewables technician Solar Power World · Guide Lists the field instruments; written by a test-equipment maker
- MIS 3002 Issue 6.0, Appendix E (model PV array test report) MCS · Standard Free for personal use. Shows which readings a PV test record holds and that the test instrument is recorded.
Latest Renewable Energy jobs
No title matches the role right now, so these are the latest jobs in the same category.
No live jobs to show right now. Check back soon, or browse every green job.
Spot a problem with this topic?
Tell us what is wrong, missing or unclear here. Your note is attached to this topic.
Notes are sent from this page with JavaScript on. Without it, write to us on the contact page.