Noise, dust, fumes, vibration and exposure limits
Occupational hygiene is measuring and controlling noise, dust, fume and vibration that harm health slowly. You will be able to write an exposure assessment and know when sampling or a hygienist is needed.
- Core
- Intermediate
- about 12 hours
Written by the GreenHired editorial teamSources last checked 20 November 2026How we research roadmaps
Measurement comes late in a hygiene job, and sometimes second. The steps run: recognise the exposure and who meets it, compare it with a recognised limit, choose controls from the top of the hierarchy, then check that the controls work, with a measurement in step four and sometimes in step two. Used as a ritual it proves little, so decide what question a measurement answers before anyone buys a pump.
A one-page assessment for a sanding bench
A small workshop sands hardwood panels at one bench, and the work is done most days. Here is what goes on the page, line by line (an invented workshop, so the page is an illustration, not advice for a real site):
- Exposure: wood dust, made by the work itself, as HSE’s COSHH guidance notes (more on this in chemical safety and COSHH).
- Who and for how long: two sanders for most of a shift, plus the cleaner who sweeps afterwards. Do not forget the cleaner.
- The limit and its source: look up the substance in EH40, and write down the edition. If it has no listed limit, say so: HSE’s COSHH page still requires you to protect workers from exposure.
- The control in place: a hood on the bench. Ask when it was last examined and tested, and whether the commissioning report exists.
- What you would measure: perhaps personal samples across a full shift. The question is whether the control works well enough.
- Who is competent: a hygienist or consultant plans and carries out the sampling. You brief them, read the report and turn it into actions.
A result with no note of the task and the conditions cannot be compared next year, so keep the note with the result.
Reading a noise result against HSE’s levels
A competent person reports a daily average of 91 dB(A) at a press operator’s ear, before any hearing protection is counted. The 91 is a made-up number for the example. Against HSE’s levels it sits like this:
- 80 dB(A): assess the risk, give information and training. The result is above it.
- 85 dB(A): hearing protection and protection zones. The result is above this too.
- 87 dB(A): the exposure limit value, which takes hearing protection into account. The operator’s protected exposure must not exceed 87.
The hierarchy, set out in hazard, risk and controls, says to look at the machine first: quieter equipment, enclosure, fewer hours at the press. Defenders come last, and only help if they fit and are worn. Whether hearing checks apply is a separate question, covered in health surveillance and occupational health, and hand-arm vibration and awkward tasks overlap with ergonomics and work-related stress. Exposure limits differ by region and change, so quote the source and edition each time.
What you will learn
- How exposure limits work: an airborne concentration or noise level averaged over a time, and what that does and does not tell you about risk.
- The difference between exposure (what is in the air or at the ear) and dose (what the body takes in), and why monitoring is separate from health surveillance.
- When noise needs assessing and which action levels apply in Great Britain and in the United States.
- Why local exhaust ventilation and respirators fail in practice, and the checks that catch the failure.
- How to keep monitoring and test records that an inspector or a doctor can use years later.
The parts of this topic
Workplace exposure limits (WELs and PELs)about 1 hour
What an exposure limit is, who sets it, how many substances have one and what to do when a substance has none.
A workplace exposure limit is an airborne concentration averaged over a set period. In Great Britain HSE approves them and lists them in EH40. HSE says only about 500 of the many thousands of substances used at work have one, and carcinogens, mutagens and asthmagens must be controlled to as low as reasonably practicable whatever the number (as read on 20 November 2026). In the US, OSHA publishes permissible exposure limits. A limit can be met on the day of sampling while the process changes next month. Meeting a number does not prove safety.
- COSHH: workplace exposure limits HSE (United Kingdom) · Guide
- Permissible Exposure Limits annotated tables OSHA (United States) · Dataset
Exposure, dose and routes of entryabout 1 hour
Separate what is in the air from what reaches the body, and know when biological monitoring answers a different question.
Exposure is the concentration a worker meets. Dose is what the body takes in by breathing, skin contact or swallowing. Personal air monitoring, HSE says, measures how much of a substance a worker inhales, while biological monitoring measures how much has entered the body. Gloves that leak, for instance, give a worker a skin dose that an air sample never shows. HSE also stresses that monitoring measures control, not anyone's health, so it is not the same as health surveillance.
- COSHH: monitoring the control of exposure HSE (United Kingdom) · Guide
Sampling basics and record keepingabout 1 hour
Know when sampling is needed, who should do it, and what a useful monitoring record contains.
Sampling is done to show compliance with a limit or that controls work well enough. A competent person plans it: which tasks, which workers, how long, which method, and what the results mean. HSE publishes methods for measuring hazardous substances (the MDHS series) used by laboratories and consultants. One short sample on a quiet day proves little, and results filed with no note of the task, the controls running or the conditions cannot be compared later. Example: personal pump samples across a full shift on welders at two stations.
- Methods for the Determination of Hazardous Substances (MDHS) HSE (United Kingdom) · Guide
Noise assessments and hearing protectionabout 1 hour
Know the action levels, how to estimate daily exposure and when hearing protection and zones are required.
In Great Britain, HSE says the level at which employers must assess the risk and give information and training is 80 dB(A). The level for hearing protection and protection zones is 85 dB(A) (daily or weekly average), and the exposure limit value is 87 dB(A), taking hearing protection into account. In the United States OSHA's standard requires a hearing conservation programme at an 8-hour average of 85 decibels (values as read on 20 November 2026). Where a shift mixes quiet and loud tasks, the HSE calculator combines them. Ear defenders only help if they fit and are worn.
- Noise: advice for employers HSE (United Kingdom) · Guide
- Noise exposure calculators HSE (United Kingdom) · Tool
- Noise at work: the Noise Regulations 2005 HSE (United Kingdom) · Guide States the 80, 85 and 87 dB(A) values.
- 29 CFR 1910.95 Occupational noise exposure OSHA (United States) · Law or regulation
Hand-arm and whole-body vibrationabout 1 hour
Spot jobs with vibrating tools or vehicles and know what controls and checks apply.
Hand-held power tools can damage blood vessels, nerves and joints (hand-arm vibration), and driving certain vehicles can cause back and muscle pain (whole-body vibration). Both are covered by HSE guidance. In a grinding task the tool, the trigger time and the worker's grip all affect exposure, so the fix may be a different tool and rotation rather than gloves. Symptoms build slowly and are reported late, so early questions and surveillance matter. Hand-arm vibration syndrome is a reportable disease in Great Britain.
- Vibration HSE (United Kingdom) · Guide
- Hand-arm vibration HSE (United Kingdom) · Guide
Local exhaust ventilation: commissioning and testingabout 1 hour
Check that extraction works on day one and keeps working: commissioning, regular examination and test, and what a failed system looks like.
Local exhaust ventilation pulls dust, fume or vapour away through a hood or booth. HSE says to commission a system so you know it controls exposure from day one, and to keep the commissioning report as the benchmark for later tests. Example: a welding bench where the hood has been moved away from the fume shows why airflow has to be measured, not assumed. HSE's COSHH guidance says ventilation equipment must be examined and tested at least every 14 months by a competent person (as read on 20 November 2026).
- Commission your LEV system HSE (United Kingdom) · Guide
- Controlling airborne contaminants at work: LEV (HSG258) HSE (United Kingdom) · Guide
- How to carry out a COSHH risk assessment HSE (United Kingdom) · Guide States the 14-month examination and test interval (at least) for ventilation equipment.
Respirators: selection and fit testingabout 1 hour
Respirators only protect if they fit the wearer, so know when fit testing is required and who may do it.
A respirator is the last control, not the first, and HSE says respiratory protective equipment cannot protect the wearer if it leaks, with poor fit a major cause of leaks. Each type of tight-fitting facepiece a worker uses needs its own fit test, carried out by a competent person. In the United States the OSHA respiratory protection standard sets out a fit-testing protocol. When a worker grows a beard or loses weight, the old test result no longer applies.
- RPE fit testing basics HSE (United Kingdom) · Guide
- Guidance on RPE fit testing (INDG479) HSE (United Kingdom) · Guide
Practice task
Choose a noisy or dusty task you can observe. Write a one-page exposure assessment: the contaminant or noise source, who is exposed and for how long, the limit that applies with its source, the control in place, what you would measure and who is competent to measure it.
Skills you build
Exposure limitsAir and noise monitoring basicsLocal exhaust ventilation checksRespirator fit testingHearing conservation
Resources for this topic
Every source here is free. Each link opens the provider's own site in a new tab.
- EH40/2005 Workplace exposure limits HSE (United Kingdom) · Law or regulation Free PDF. The list of limits is legally binding under COSHH. Check the current edition.
- Noise at work HSE (United Kingdom) · Guide
- Occupational noise exposure overview OSHA (United States) · Guide
- Local exhaust ventilation (LEV) hub HSE (United Kingdom) · Guide
- Respiratory protective equipment (RPE) hub HSE (United Kingdom) · Guide
- 29 CFR 1910.134 Respiratory protection OSHA (United States) · Law or regulation The US standard. Check the current text.
Live Environmental, health and safety (EHS) officer jobs
Roles whose title matches this career path.
Spot a problem with this topic?
Tell us what is wrong, missing or unclear here. Your note is attached to this topic.
Notes are sent from this page with JavaScript on. Without it, write to us on the contact page.