Energy, carbon and sustainability reporting basics
Energy audits and greenhouse gas inventories in outline: scopes 1, 2 and 3, emission factors, UK ESOS and SECR, and ISO 50001. You will build a small inventory and answer a questionnaire from traceable data.
- Optional
- Intermediate
- about 12 hours
Written by the GreenHired editorial teamSources last checked 20 November 2026How we research roadmaps
Before collecting a single bill, decide what the number is for: a customer questionnaire, a UK regulation, or your own baseline. Then fix the boundary, collect activity data from bills and meters, apply one published factor set and record its year. A total you cannot trace to a bill and a factor is worth less than a rough one that is honestly labelled. This topic is optional because carbon is a specialism, but the method is short.
Building the inventory from the bills
Your aspects register and baselines can feed the activity data. A small site’s inventory from three bills looks like this:
- Company vans, scope 1: 12,000 litres of diesel x 2.5 kg CO2e per litre = 30,000 kg, or 30 tonnes.
- Gas boiler, scope 1: 40,000 kWh x 0.2 kg per kWh = 8,000 kg, or 8 tonnes.
- Electricity, scope 2: 90,000 kWh x 0.2 kg per kWh (a made-up grid average) = 18,000 kg, or 18 tonnes location-based. The site buys a renewable tariff and the supplier’s made-up factor is 0.05, so the market-based figure is 90,000 x 0.05 = 4,500 kg, or 4.5 tonnes.
The quantities and factors above are invented, to show the arithmetic, and are not real: take real factors from a published set, such as the UK government conversion factors, for the year of your data.
Reading the totals
Scope 1 totals 38 tonnes. Scope 2 is 18 tonnes location-based and 4.5 market-based, and you report both. On the location-based total of 56 tonnes (30 + 8 + 18), the vans are more than half, so the vans are where to look first. Add a note of what is missing, such as refrigerant top-ups with no records.
Is the organisation covered by ESOS at all?
Ask finance before planning any ESOS work. GOV.UK says a corporate group qualifies if at least one UK group member meets the large-undertaking definition, so a small site inside a large group may still be in scope. ESOS and SECR are different duties, and ISO 50001 can be an ESOS route only on the conditions in the parts above (see ISO 31000 and ISO 50001). Read the current GOV.UK pages for each, because dates and thresholds change.
The limits of the EHS role
An EHS officer can be handed the carbon figure because they already know the meters and the records. Say what you can and cannot verify, and who signs the number. Management systems basics shows where an energy objective fits. Answer questionnaires with the total by scope, the boundary, the factor set and year, and the known gaps.
What you will learn
- What scope 1, scope 2 and scope 3 emissions are, and how to draw a simple organisational boundary.
- The difference between location-based and market-based scope 2 reporting.
- How to collect activity data and apply published emission factors.
- What the UK's ESOS energy assessment scheme and SECR require, and where ISO 50001 fits as a route.
- How to answer a customer's or an investor's sustainability questionnaire honestly.
The parts of this topic
Scope 1, 2 and 3 and the inventory boundaryabout 1 hour
Separate direct emissions from purchased energy and from value-chain emissions, and decide what is in the inventory.
EPA describes a greenhouse gas inventory as a list of emission sources and the emissions quantified using standardised methods. Scope 1 emissions are direct, from sources the organisation owns or controls, such as boilers, furnaces and vehicles; scope 2 emissions come from purchased electricity, steam, heat or cooling. Scope 3 covers other indirect emissions. Fuel for company vans, for instance, is scope 1, and the site's electricity is scope 2. Keep the boundary the same each year, or say what changed, so the totals can be compared.
- Scopes 1 and 2 emissions inventorying and guidance US EPA · Guide Aligned with the GHG Protocol Corporate Standard.
Scope 2: location-based and market-basedabout 1 hour
Report purchased electricity two ways: by the grid average and by the contracts you hold.
The GHG Protocol Scope 2 Guidance sets out two methods for reporting emissions from purchased electricity: the location-based method reflects the average grid mix where energy is used, and the market-based method reflects the contractual instruments a company buys. The page lists eight quality criteria that contractual instruments must meet and notes that a public consultation on the guidance ran from October 2025 to January 2026. Example: a site on a renewable tariff reports a lower market-based figure but the same location-based one. Report both, not just the more flattering one.
Activity data, emission factors and data requestsabout 1 hour
Multiply activity data (kWh, litres, kilometres) by an emission factor, document each source and handle questionnaires honestly.
The UK government publishes conversion factors that let users calculate emissions from activity data such as fuel volume, electricity kWh or distance travelled, for scope 1, 2 and 3 separately; the page shows an update in June 2026, so use the right year. In the basic sum, 12,000 litres of diesel multiplied by the diesel factor gives scope 1 emissions. Customers' and investors' sustainability questionnaires can ask for these totals. Answer only with figures you can trace to bills and a stated factor set.
- UK government GHG conversion factors for company reporting GOV.UK (DESNZ) · Dataset
UK Streamlined Energy and Carbon Reporting (SECR)about 1 hour
Some UK companies and limited liability partnerships must report energy use and emissions in their annual reports.
GOV.UK's environmental reporting guidelines document helps companies and limited liability partnerships comply with the Streamlined Energy and Carbon Reporting regulations, including greenhouse gas reporting. The page shows the guidance was last updated in 2019 (as read on 20 November 2026), so check whether newer rules or thresholds apply to the organisation before relying on it. A large UK company, for instance, includes energy use, emissions and an intensity ratio in its annual report. ESOS and SECR are separate duties with different purposes and rules.
- Environmental reporting guidelines including SECR GOV.UK · Guide
ESOS: the UK energy assessment schemeabout 1 hour
Large UK organisations assess energy use every four years, using an audit or an ISO 50001 route, with a lead assessor sign-off in most cases.
GOV.UK says ESOS is a mandatory energy assessment scheme for UK organisations that qualify, with an assessment every four years covering buildings, industrial processes and transport. For phase 4 a large undertaking employs 250 or more people, or has turnover above 44 million pounds and a balance sheet above 38 million pounds, tested on 31 December 2026. The compliance date is 5 December 2027, and routes are an energy audit or ISO 50001 certification (all as read on 20 November 2026). Example: appointing a lead assessor early. Read the current ESOS guidance rather than this summary.
- Energy Savings Opportunity Scheme (ESOS) GOV.UK · Guide
ISO 50001 as a compliance route and management systemabout 1 hour
An energy management system standard can replace a stand-alone ESOS audit if its certification meets the scope and date conditions.
GOV.UK says an organisation may comply with ESOS using ISO 50001 certification covering significant or total energy consumption, with the certificate issued after 5 December 2023 and valid at the compliance date; lead assessor sign-off is not needed where the certification covers the consumption or total use is below 40,000 kWh. A certification body describes ISO 50001:2018 as the international standard for energy management systems. A provider says certification means ESOS compliance, but GOV.UK sets conditions, so a certificate does not automatically cover everything.
Where energy and carbon meet the EHS roleabout 1 hour
Energy and carbon often sit inside the environmental management system alongside compliance obligations.
EPA says an environmental management system can address non-regulated issues such as energy conservation as well as regulatory requirements, and that it promotes stronger operational control. In a small organisation the EHS officer can end up as the person asked for the energy data, the carbon figure and the sustainability questionnaire. An officer might build the energy and waste baseline for the aspects register and reuse it for customer requests. Take on the carbon number only if you have the time, tools and authority to verify the data behind it.
- Basics of an environmental management system US EPA · Guide
Practice task
Build a simple annual inventory for a small site, real or invented: fuel, electricity and refrigerant use, activity data from bills, emission factors from the UK government set or EPA, and totals by scope. Add a one-page note listing your boundary, your data gaps and the three biggest sources.
Skills you build
Greenhouse gas scopesEmission factorsEnergy audit basicsESOS awarenessSustainability data requests
Resources for this topic
Every source here is free. Each link opens the provider's own site in a new tab.
- GHG Protocol Corporate Accounting and Reporting Standard GHG Protocol · Standard Free PDF download on the page.
- ISO 50001 certification overview (provider page) ISOQAR · Guide A certification body's summary. The standard itself is paid.
- Industrial Training and Assessment Centers (ITAC) US Department of Energy programme · Tool No-cost energy assessments for eligible US manufacturers, run by university teams. Check eligibility on the page.
- Inventory of US greenhouse gas emissions and sinks US EPA · Dataset
Live Environmental, health and safety (EHS) officer jobs
Roles whose title matches this career path.
Spot a problem with this topic?
Tell us what is wrong, missing or unclear here. Your note is attached to this topic.
Notes are sent from this page with JavaScript on. Without it, write to us on the contact page.